Most varieties of foam have a higher r value per inch than fiberglass cotton or cellulose.
Rigid foam r value per inch.
Expanded polystyrene foam eps is the cheapest and least used foam board product on the market.
R value is not entirely a function of the thickness of the material as the facing material and type of foam used will affect the r value of the material.
Rigid foam can be used in walls roofs and foundations for retrofits or new construction.
Rigid foam r values range from r 1 for 1 4 inch thick sheathing panels to r 15 for 3 inch thick panels.
Loose fill such as fiberglass cellulose mineral wool 8 23 inches thick 30 50.
It s made of environmentally sound closed cell polyisocyanurate foam bonded to a durable white matte non glare aluminum facer and a reflective reinforced aluminum facer.
R value cost sq.
Open cell polyurethane spray foam 3 5 inches thick 12 6.
Eight inches of poor quality insulation may have a higher and better r value than one inch of top.
R 3 2 polyisocyanurate rigid foam insulation board r matte plus 3 thermasheath 3 is rigid foam r matte plus 3 thermasheath 3 is rigid foam plastic thermal insulation board.
Thickness inches r value in i p imperial rsi r value in metric 0 5.
The r value for foamular xps insulation is provided from testing at two mean temperatures 40ºf and 75ºf and from two aging conditioning techniques 180 day real.
Rmax r matte plus 3 1 2 in.
Additional r value for a masonry wall constructed using these materials needs to add the insulating value of additional wall components typically included such as 1 solid foam polyisocyanurate r 8 extruded polystyrene r 5 expanded polystyrene r 4 or 1 of perlite r 2 7 and for an exterior air film winter no wind r 0 17 an interior.
Falls in the middle of the three types of rigid foam insulation in both cost and r value used most in walls or below grade applications recyclable and at about r 5 per inch costs around 42 per sq.
In comparison an inch of blown fiberglass insulation has an r value of 3 1 3 4 and an inch of blown cellulose in an attic has an r value of 3 2 3 7.
Closed cell polystyrene spray foam 1 inch thick 6 5.
The time of testing.
For a 1 in thick 4 8 panel comes unfaced or with a number of different plastic facings.
Fiberglass insulation packs in more r value per cubic inch than rigid foam insulation does.
Expanded polystyrene eps extruded polystyrene xps and polyisocyanurate.
As a benchmark one inch of solid wood has an r value of 1.
There are three main types of rigid foam insulation.
Conditioned per atsm c1289 test method astm c518 1 2.
This product typically has an r value of 3 6 to 4 0 per inch of thickness.
Expanded polystyrene insulation is similar to the foam used for packing peanuts and it s typically used for insulated concrete forms also knows as icf s.